Leave Your Message
Products Categories
Featured Products

RAVS for Transient Fault in Power Supply

RAVS is a monitoring device specifically designed for online long-term high-frequency recording of sudden changes in system voltage. RAVS can monitor system voltage in real-time online, monitor voltage fluctuations and power quality of the system, and has the characteristics of high accuracy, high precision, high response speed, and high stability.

RAVS is unable to accurately capture information on short duration system voltage fluctuations using commonly used waveform recorders or power quality monitoring devices in the market. RAVS can accurately monitor and record the changes in system voltage for a long time, and conduct real-time analysis of voltage issues such as voltage flicker, voltage oscillation, voltage deviation, voltage surge, voltage grounding, voltage short circuit, etc. Based on the recorded analysis results, it provides accurate quantitative parameters and reasonable solutions for fault warning, fault analysis, and fault resolution.In addition, RAVS can also perform real-time online monitoring of conventional power quality such as system voltage, current, power, THD, and imbalance.

    Functional Features

    1 Beidou/GPS timing can be connected to a separate external time synchronization device or shared with the original system clock
    2 Voltage flicker If the difference between the maximum peak values of the two adjacent wave heads of the voltage waveform exceeds the set threshold, immediately start recording(-1~+30s )
    3 Voltage sag if the voltage of any phase is lower than the set threshold, immediately start recording(-1~+30s )
    4 Voltage oscillation Oscillation is difficult to prevent and poses serious harm. When the oscillation amplitude exceeds the set threshold, immediately start recording(-1~+30s )
    5 Voltage deviation The transient voltage waveform contains a DC component, and when the amplitude exceeds the set threshold, the recording is immediately initiated(-1~+30s )
    6 Voltage surge External surge, power transmission, protrusion, sudden load rejection, etc., exceeding the set threshold, immediately start recording(-1~+30s )
    7 Voltage grounding When a single-phase grounding fault occurs in the system, accurately identify the fault and its occurrence time, and immediately start recording(-1~+30s )
    8 Voltage short circuit When a phase to phase short circuit fault occurs in the system, accurately identify the fault and its occurrence time, and immediately start recording(-1~+30s )
    9 Routine power quality monitoring Voltage fluctuation, load current, power analysis, THD monitoring, imbalance monitoring, etc.
    No need to install other power quality monitors.
    10 Main spec Sampling frequency 100kHz; monitor 0-63 harmonics, inter harmonics, and higher harmonics; 4G memory, 64G solid-state drive; LCD high brightness TFT LCD touch screen; 10 inches; Resolution 800 × 600; one × RS-232/485, 1 × RS232, 4 × USB2.0, 1 × VGA, 1 × GigaLAN

    products advantage

    No items Main technical features
    1 Technical level High sampling frequency:20kHz(sampling time:83ms → 50ms)
    More duration time recording:--1~+30s (panoramic recording)
    More duration time when power loss:60s
    Accurate time synchronization function:Beidou or GPS
    Stronger analysis capabilities:Real time analysis of various voltage issues
    Solution Recommendation:Based on the analysis results of panoramic recording, recommend the most reasonable solution
    2 Process level Change the touch screen to 10 inches
    Improve wiring methods: wiring terminals, wiring methods, etc
    High strength anti vibration structural design
    Artwork style full art design
    • ROFS, specially designed for low-voltage systems;
    • Longer recording time;
    • Real time monitoring of circuit breaker status;
    • Powerful data analysis and networking capabilities.

    Leave Your Message